『Price of Weiliba flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

What is the difference between Anuba flowmeter and Velbar flowmeter? Please do not copy or excerpt, I hope the answer is simple and easy to understand. O...
The main difference is the probe part. The probe structure of Anuba has two types: circular and diamond, as shown in Figure (a), (scattered back b). The probe of Weiliba is equipped with a high-strength single piece dual chamber anti-seepage structure cover, and the low-pressure pressure tapping hole is flush sealed on both sides. Multiple sets of positive and negative pressure tapping holes are designed. As shown in the figure (c), compared to the anti blocking effect of the Velocimeter, the anti blocking effect of the Velocimeter is still better.
2. The structure of the Velocimeter with the averaging tube is composed of three parts: an integrated sensor, a differential pressure transmitter, and an accumulator.
. 1. The integrated power bar sensor of the core measurement unit adopts a streamlined dual cavity stainless steel structure, and the surface is roughened to form a turbulent boundary layer. The high-pressure tapping hole is set on the metal curved surface at the front end of the probe, forming a high-pressure barrier to prevent particles from entering; The low-pressure tapping hole is located in front of the side rear airflow separation point, and the double row symmetrical layout greatly reduces the risk of blockage. The differential pressure transmitter of the signal conversion module precisely senses the pressure difference between the total pressure of the high-pressure chamber and the static pressure of the low-pressure chamber, which directly reflects the average flow velocity of the fluid. After temperature compensation and li
_600x400.jpg)
3. Installation and commissioning of Velbar flowmeter
Installation and commissioning of Velbar flowmeter
1. Preparation for installation Before the formal installation of Velbar flowmeter, sufficient preparation work is required.
. Instrument testing personnel need to go deep into the site to thoroughly understand the distribution of the tested medium pipeline, including key parameters such as pipeline diameter and wall thickness. These pieces of information are crucial for determining the installation location, selection, and subsequent debugging of flow meters. At the same time, it is necessary to clarify the minimum flow rate, common flow rate, maximum flow rate
Current position > News detail